Igwe na-asa igwe Microchannel condenser

Igwe na-asa igwe Microchannel condenser

A na-etinye Hylita MCHE n'ime ụlọ kọmpụta AC, dị ka teknụzụ na-ebufe ọkụ dị elu{0}, Microchannel Heat Exchangers (MCHEs) pụtara n'akụkụ dị iche iche (dịka, HVAC, refrigeration, ụgbọ ala) n'ihi nhazi nhazi ọhụrụ na uru arụmọrụ ha dị.

Okwu Mmalite

IMG20250909094238

IMG20250909094254

IMG20250909100313

IMG20250909100501

IMG20250909100812

 

Ndị na-agbanwe ọkụ Microchannel (MCHEs): Gbanwee CRAC Condensers maka arụmọrụ Center Data

Maka ebe data, Kọmputa Room Ikuku Conditioner (CRAC) na-eme ka-ma ọ bụ{1}} ezumike maka ikwado ọrụ nkesa yana iweda PUE (Irụ Ọrụ Ike). Ọkụ ọdịnala -Fin okpomọkụ na-adakarị mkpụmkpụ-ha pere mpe, anaghị arụ ọrụ nke ọma, yana nnukwu nlekọta-. BanyeNdị na-agbanwe ọkụ Microchannel (MCHEs): ejiri microscale eruba ọwa (0.1-2 mm), arụnyere ihe niile{2} aluminom, na vacuum brazing, MCHE na-edozi isi ihe mgbu ndị a ma na-ebuga uru a na-ahụ anya maka arụmọrụ data center. N'okpuru bụ ka ha siri pụta, gbakwunyere tweaks omenala na-ebuli mmetụta ha.

Uru Ngwa Isi: Dozie isi ihe mgbu kacha ukwuu

MCHE abụghị naanị 'emeziwanye' na condensers ọdịnala{0} ha na-akọwapụta ihe ga-ekwe omume maka ebe data gbadoro anya na arụmọrụ, oghere, ọnụ ahịa na ntụkwasị obi.

1. 30–50% arụmọrụ mbufe ọkụ dị elu=ala PUE

Ebe data na-alụ ọgụ idobe PUE n'okpuru 1.3- na MCHE bụ ngwa agha nzuzo. Ọwa microscale ha na-emepụta nnukwu mbara elu (200-350 m²/m³, 2–3x nke tube{15}} ụdị fin), na-amanye refrigerant (dị ka R134a ma ọ bụ R410A) n'ime nnukwu ọgba aghara (nọmba Reynolds Re> 2300). Nke a na-ebelata nguzogide okpomọkụ, na-akpali ọnụọgụ nnyefe okpomọkụ gaa na 400-600 W/(m²·K) (vs. 200-300 W/(m²·K) maka tube-fin).

Ihe nke a pụtara maka gị: Maka ibu jụrụ oyi nke 100 kW, MCHE na-egbutu okpomọkụ site na ogo 3-5. Ndabere ogo 1 ọ bụla na-ebelata ojiji ike compressor site na 2-3%, na-atụgharị gaa na 25-35% oriri ike CRAC dị ala. Maka etiti data etiti 1000 m², nke ahụ bụ 30,000–42,000 kWh na nchekwa ọkụ eletrik kwa afọ{15} na PUE si na 1.4 gbadata ruo n'okpuru 1.25.

Zuru oke maka: Ebe data dị elu- njupụta (ike njupụta> 300 W/m²) ma ọ bụ megharịa nkeji CRAC ochie (ọ dịghị mkpa ịgbasa oghere iji kwalite oyi).

2. 30–50% Nta, 40–60% Mkpa ọkụ: Chekwaa oghere Center Data bara uru

Oghere ebe etiti data dị ọnụ-na tube ọdịnala{1}} fin condensers na-efunahụ ya. MCHEs' niile -aluminom flat-tube + integrated fin design na-ewepụ nnukwu ọla kọpa na agbagọ na oghere fin nke na-eke tube- ụdị fin.

Maka nhazi ikuku 100 kW{1} jụrụ oyi:

Mpịakọta: MCHE na-ebuli ~0.8 m³ (vs . 1.2-1.3 m³ maka tube- fin), na-adaba n'ụzọ dị mfe na akụkụ ma ọ bụ nkuku.

Arọ: Na ~80 n'arọ (vs . 150 n'arọ maka tube - fin), MCHE dị mma maka ụlọ CRAC n'elu ụlọ{3} ha na-ebelata ibu ụlọ ma belata ụgwọ ntinye (ọ dịghị mkpa ebuli ibu dị arọ).

3. 50–70% Igwe nju oyi pere mpe: belata ọnụ ahịa wee zute iwu gburugburu.

Igwe nju oyi dị ka R410A dị ọnụ ma na-ahazi ya (n'ihi ụkpụrụ EU F-Gas na nke ChinaNtụle Nleba Nleba Anya na Ọ Dị Ala {{0}Kabon Maka Ụlọ Ọrụ Data). Obere ọwa MCHEs (1/3–1/2 nke tube -fin) na-ebelata mkpa ngwa nju oyi:

Sistemu 100 kW na-eji R410A chọrọ naanị 2.5–3.5 n'arọ nke refrigerant (vs{4}}–10 n'arọ maka tube-fin){7}} na-echekwa ~300–390 CNY kwa otu nkeji n'ihu.

Ebe ntapu dị ole na ole (40% na-erughị tube-fin, ekele maka nkụnye ejikọtara ọnụ) pụtara ihe ize ndụ dị ala na gburugburu ebe obibi na enweghị nnukwu refrigerant elu{2}}.

4. Nguzogide corrosion & MTBF nke awa 10,000: Mee ka CRAC na-agba ọsọ 24/7

Ebe data na-agba ọsọ na-akwụsịghị akwụsị{0} na oge nkwụsị bụ nnukwu ọdachi. Ọkụ ọdịnala - fin condensers na-ada n'isi ụtụtụ n'ihi ọla kọpa-aluminom galvanic corrosion, mana a na-ewu MCHE ka ọ dịgide:

Ọdịdị enweghị nkebi: Vacuum brazing na-ewepụ "ọla kọpa-aluminom gaps" (ihe na-akpalite corrosion bụ isi).

Ihe mkpuchi omenala: Epoxy ma ọ bụ polytetrafluoroethylene mkpuchi (20-50 μm gbara ọkpụrụkpụ) na-akwalite nguzogide nnu site na awa 500 ruo ihe karịrị awa 1500.

Nsonazụ ahụ? MTBF (Akara oge n'etiti ọdịda) ruru awa 10,000 - fọrọ nke nta ka ọ bụrụ okpukpu abụọ nke tube{3} fin (awa 5,000–6,000). Ndozi pere mpe=obere oge maka etiti data gị.

Ndagharị nka nka omenala: Mee MCHEs ka ọ rụọ ọrụ maka CRAC gị

MCHE abụghị ihe nnọchi "dodo{0}na"{1} ha chọrọ tweaks iji kwekọọ mkpa pụrụ iche nke CRAC. Nke a bụ otu anyị si ebuli ha maka ebe data:

1. Smart Design maka Mgbanwe ibu & obere mkpọtụ

Ọwa gafere ọtụtụ{{0}: Ihe nkesa na-ebu ibu n'ehihie ma na-adaba n'abalị. MCHE na-eji ọwa mmiri na-asọ asọ nke ngalaba 2-4, jikọtara ya na valvụ mgbasawanye eletrọnịkị, iji dozie mgbaba refrigerant: ikike zuru oke maka ọnụ ọnụ, ikike akụkụ maka lulls. Nke a na-ezere "adịghị arụ ọrụ dị ala{{4}" nke na-emebi condensers omenala otu -.

Nkwụ dị jụụEbe data chọrọ mkpọtụ Ihe na-erughị ma ọ bụ haha ​​na 60 dB (A). Ndị MCHE na-eji nku dị warara{2}}pitch louvered (1.8–2.2 mm spacing) na obere-ndị na-efe ikuku (1.5–2.0 m/s) -ịbelata mkpọtụ site na 3–5 dB (A) vs. tube{12}} fin, yabụ (ọrụ na mmezi) otu na-arụ ọrụ adịghị atụgharị.

2. (Corrosion & Clogging Protection): Ewuru maka gburugburu ebe data Center

Uzuzu, uzuoku batrị UPS, na oke mmiri bụ ihe egwu etiti data -MCHE na-emeri ha n'isi{1} na:

Ihe mkpuchi mkpuchi corrosion abụọ- oyi akwa{1}: Passivation chromate (5-10 μm) na-eme ka adhesion dịkwuo elu, ebe akwa oyi akwa epoxy (20-30 μm) na-egbochi mgbasa ozi na-emebi emebi. Nnwale na-egosi na ọ na-eguzogide nchara maka ihe karịrị afọ 8 na ebe data.

Mmiri{0}} ihe ndozi n'akụkụ (maka CRAC jụrụ oyi{1}): Ọwa MCHE (1-2 mm) na-enwekarị ike itolite - yabụ anyị tinye:

Ihe nzacha ihe nzacha igwe anaghị agba nchara 100 iji jide adịghị ọcha.

Ọwa agbadoro (oghere ntinye 1 mm → 1.5 mm outlet) iji belata ọsọ ọsọ -ọnụego na-ebute ọnụ ọgụgụ.

Nri{0}} ihe mgbochi ọkwa ọkwa (dịka ọmụmaatụ, polycarboxylic acid) ịgbatị oge nhichapụ ruo ọnwa 12 (vs. 6 ọnwa maka tube-fin).

3. Njikọ CRAC na-enweghị nkebi: Enweghị ihe mkpofu, enweghị ntapu

MCHE na-arụ ọrụ kacha mma mgbe ejikọtara ya na sistemụ CRAC{0} anyị na-ebuli njikọ ọ bụla:

Fan dakọtara: MCHE fins nwere 15-20% ikuku nguzogide karịa tube{2}} fin. Anyị na-eji obere - static - ndị na-akwado nrụgide (50–80 Pa) yana ọsọ okpu na ihe na-erughị ma ọ bụ ha nhata 1400 rpm iji chekwaa ike n'achụghị ihe jụrụ oyi.

Ọhụụ ihiwe-: nkụnye eji isi mee ejikọta ọnụ na-ebipụ ọnụ ọgụgụ interface site na 8–12 (tube{2}}fin) ruo 2–4. Ugboro abụọ - ferrule akara na-edobe ntapu ihe na-erughị ma ọ bụ ha nhata 1×10⁻⁹ Pa·m³/s (kwa ule ntapu helium)- dị mkpa maka nchekwa refrigerant.

Ihe kpatara MCHE ji bụrụ ọdịnihu nke CRAC Condensers

Maka ebe data, MCHE abụghị naanị ihe mgbanwe ọkụ ka mma - ha bụ ụzọ isi nweta ebumnuche nkwado, belata ọnụ ahịa, ma mee ka sava na-arụ ọrụ nke ọma. Ma ị na-ewu ụlọ njupụta{2} dị elu ma ọ bụ na-ebulite CRAC ochie, MCHE na-ebupụta arụmọrụ, nchekwa ohere na ogologo oge ị ga-achọ ka ị nọgide na-asọmpi.

Ị dịla njikere ịgbanwe condensers CRAC gị? Nyochaa ka MCHE nwere ike isi wedata PUE gị wee kwalite arụmọrụ center data gị taa.

 